        Labculture® Reliant Class II, Type A2 Biological Safety Cabinets (E-Series)

        Labculture® Reliant Class II, Type A2 Biological Safety Cabinets (E-Series)
        ULPAISOCIDENSFUL
        • Latest generation DC ECM Motor made in USA, as the heart of the cabinet
        • Negative pressure plenum surrounds the contaminated positive pressure plenum. No fabric bags are used.
        • Long-life ULPA filters for supply and exhaust (per IEST-RP-CC001.3) with 99.999% efficiency for particle size between 0.1 to 0.3 microns
        • Coved one-piece work surface contains spillage. The absence of screws or connectors in the work zone facilitates ease of cleaning and decontamination
        • One-piece back wall with radiused cove corners to ensure thorough cleaning and decontamination
        • Angled supply filter matches cabinet profile to achieve best downflow uniformity
        • Zero volt relay output port enables monitoring of blower and alarm
        • Frameless sash that is easier to clean
        • Ergonomically-angled front improves reach and comfort
        • Actual work access height is 25 mm (1") higher that tested sash opening
        • Raised airflow grille maintains safety by preventing blockage
        • Esco IsocideTM antimicrobial coating on all painted surfaces minimizes contamination
        • Enhanced side-captured zones optimize containment
        • Work area on Esco 0.9 meter (3') cabinet is equivalent to work area offered on larger 1.2 meter (4') conventional cabinet
        • Night setback mode / standby mode reduces power consumption while maintaining containment
        Model No. External Dimensions Internal Dimensions Airflow Velocity (Inflow) Airflow Velocity (Downflow) Electrical
        LR2-3S1-E 1115 x 852 x 1540 mm
        (44.0" x 33.5" x 60.6")
        970 x 623 x 670 mm
        (38.2" x 24.5" x 26.4")
        0.53 m/s
        105 (fpm)
        0.35 m/s
        70 (fpm)
        230 VAC
        50 Hz
        LR2-3S2-E 115 VAC
        50/60 Hz
        LR2-3S3-E 230 VAC
        60 Hz
        LR2-4S1-E 1420 x 852 x 1540 mm
        (56.0" x 33.5" x 60.6")
        1270 x 623 x 670 mm
        (50.0" x 24.5" x 26.4")
        230 VAC
        50 Hz
        LR2-4S2-E 115 VAC
        50/60 Hz
        LR2-4S3-E 230 VAC
        60 Hz
        LR2-5S1-E 1725 x 852 x 1540 mm
        (68.0" x 33.5" x 60.6")
        1570 x 623 x 670 mm
        (61.8" x 24.5" x 26.4")
        230 VAC
        50 Hz
        LR2-5S2-E 115 VAC
        50/60 Hz
        LR2-5S3-E 230 VAC
        60 Hz
        LR2-6S1-E 2030 x 852 x 1540 mm
        (80.0" x 33.5" x 60.6")
        1870 x 623 x 670 mm
        (73.6" x 24.5" x 26.4")
        0.33 m/s
        65 (fpm)
        230 VAC
        50 Hz
        LR2-6S2-E 115 VAC
        50/60 Hz
        LR2-6S3-E 230 VAC
        60 Hz
        LR2-8S1-E 2600 x 852 x 1540 mm
        (102.4" x 33.5" x 60.6")
        2440 x 623 x 670 mm
        (96.0" x 24.5" x 26.4")
        230 VAC
        50 Hz
        LR2-8S2-E 115 VAC
        50/60 Hz
        LR2-8S3-E 230 VAC
        60 Hz

        Support Stands

        • Fixed height, available
          • With casters: 711 mm (28") or 864 mm (34")
        • Adjustable height,
          • With leveling feet: (Hydraulic range) 711 mm to 762mm (28" to 30") or 864 mm (34")
        • Telescoping Feet Stand
          • Manually Adjustable: 711mm to 914mm (28" to 36") by Pins.
        • Hydraulic Stand
          • Electrically Adjustable: 711mm to 914mm (28" to 36")


        Electrical Outlets and Utility Fixtures 

        • Universal Service Fixture Kit (Air, Gas, Vacuum)
        • Thimble exhaustion
        • Air tight damper; 9.8" x 9.8" (D x H); Fits inside 10" duct


        Cabinet Accessories

        • Anti Blow Back Valve
          • Automatically shuts duct, preventing back flow in the duct, 10" diameter
        • Plastic decontamination bag for formalin decontamination on all BSC
        • Air tight cable port, installed on the right side wall
        • PVC armrest
          • Improves operator comfort, easy-to-clean. 712mm (28") standard size.
        • Ergonomic foot rest
          • Angled, helps maintain proper posture.
          • Adjustable from 3" to 11" in 1:increment.
          • Black rubber matte.
        • IV bar, with hooks
          • Maximum load is 6Kg. (13lbs)
        • Microscope viewing device
          • Factory installed; specify when ordering.
        pdfNSF Certificate
        pdfNSF Listed Cabinets July 31, 2014
        pdfUL Certificate
        pdfUL Test Report

        *NSF Certified Models: LR2-4S1-E, LR2-4S2-E, LR2-4S3-E, LR2-5S1-E, LR2-5S2-E, LR2-5S3-E, LR2-6S1-E, LR2-6S2-E, LR2-6S3-E