Your Practical Solution to cGMP Compliance
Containment Barrier Isolator – Unidirectional (CBI-U) utilizes unidirectional/laminar airflow and facilitates the isolation of a product or process while providing the required conditions (ISO Class 5/ Grade A Environment) for a sterile/aseptic environment. This equipment provides a comprehensive range of personnel and product protection in addition to protection for the surrounding work areas and the environment.
It is factory-configured to operate at positive or negative pressure in single pass or recirculating airflow. The type of application dictates the operating parameters (pressure/airflow) of the CBI-U.
APPLICATIONS
Guide to Models
CBI-U-___-___-___-__
Isolator Unit | Model | Internal Width | No. of Gloves Ports | Voltage Code | Pressure | Airflow | NUMBER of PTC | Type of PTC | Sharps Bin inside | |||||||
Containment Barrier Isolator | CBI | Unidirectional | U | 1200mm | 2G | 220-240 VAC, 50/60 Hz | 8 | Negative | N | Recirculating | R | 1 Left | L | PTC0 to PTC7 (see PTC legend) | with sharps container provision | S |
1600mm | 3G | 1 Right | R | |||||||||||||
2000mm | 4G | 110-120 VAC, 50/60 Hz | 9 | Positive | P | Single Pass/Total Exhaust | S | Both Left and Right | B | without sharps container provision | 0 | |||||
No PTC | 0 |
LIST OF OPTIONS for CBI Models | CBI-U | CBI - T | CBI-III | CBI-H | |||
4" Split Butterfly Valve (for powder discharge of powder below isolator chamber) | ? | ? | |||||
Adjustable Hydraulic Stand (based on operator ID input) | ? | ? | ? | ||||
Exhaust Box (with automated dampers with inflatable seals or manual with valve) | ? | ? | ? | ||||
Anti-blow back damper box | ? | ? | ? | ||||
Automated Pressure Hold Test | with Client Supplied Compressed Air | ? | ? | ? | ? | ||
with On-board Air Compressor | ? | ? | ? | ? | |||
Bag Welder with Table Bag-out Port |
? | ? | ? | ||||
Bio Dunk Tank Bag Out Port |
? | ? | |||||
Mobile Biodecontamination BioVap TM | ? | ? | ? | ||||
Carbon Filter | ? | ||||||
Convertible to Class 1 cabinet | ? | ||||||
Integration of small scale aseptic or potent tablet/capsule etc… | ? | ? | ? | ? | |||
Double-sided access | ? | ? | ? | ||||
Manual Drain Ball Valve (for client controlled CIP/WP) must order with inner pass-through inflatable sealed doors. | ? | ? | |||||
Electrical Outlet (IP66) | IP 66 | ? | ? | ? | ? | ||
ATEX Zone 1/21 (only for internal environment) | ? | ? | ? | ||||
ATEX rating up to zone 1/21 internally only (ATEX fan, “IS” signals for internal door sensor/push button) | ? | ? | |||||
Glove Leak Tester | ? | ? | ? | ? | |||
Formalin Vaporizer (auto neutralization and purge cycle) | ? | ? | ? | ||||
H2O2 Monitoring (sensor is not integrated with HMI) | ? | ? | ? | ||||
Liquid Water Entry / Exit Ports | ? | ? | |||||
N2 Purge for Process Chamber | ? | ||||||
Ø250 mm Product Waste Bag Out Ports / | ? | ||||||
Battery option to maintain EM interlock during power outage or E Stop | ? | ? | ? | ? | |||
Particle Counter | Portable Paricle Counter (Non-viable) | ? | ? | ? | |||
Microbial Air Samples (Viable Particle Counter) | ? | ? | ? | ||||
Product Waste Entry / Exit Ports | ? | ? | |||||
RTPØ 105, 190, 270 - Alpha | ? | ? | ? | ? | |||
RTPØ 105, 190, 270 - Beta Canister | ? | ? | |||||
RTPØ 105, 190, 270 - Beta Liner | ? | ? | |||||
RTPØ 350, 460 - Alpha, Beta Liner, Beta Canister | ? | ? | ? | ||||
Service Fixtures (Vacuum, Nitrogen, Compressed Air, Nozzle for BioVap) | ? | ? | ? | ? | |||
Spray Ball (CIP) with Manual Ball Valve | ? | ||||||
Spray Gun (WIP) with Manual Ball Valve | ? | ? | |||||
Sterile Continuous Liner | ? | ? | ? | ||||
Sterility Test Pump | ? | ||||||
Temperature and Relative Humidity Monitoring (only for process chamber) | ? | ? | ? | ? | |||
Rear view monitor | ? | ? | ? | ? | |||
UV Lamp | ? | ? | |||||
Weighing Scale Granite Slab | ? | ? | ? | ||||
Sharps (inside) | ? |
EQUIPMENT INTEGRATION/ CUSTOMIZATION EXAMPLES | CBI-U | CBI - T | CBI-III | CBI-III/1 | |||
Autoclave | ? | ? | |||||
Analytical Balance | ? | ? | ? | ? | |||
Biosafety Cabinet | ? | ||||||
CCTV Camera | ? | ? | ? | ||||
CCTV Camera Provision | ? | ? | ? | ||||
Fume Cabinet Integration | ? | ||||||
Vacuum Oven / Tray Dryer integration | ? | ||||||
Non C02 Incubator Integration | ? | ? | ? | ||||
CO2 Incubator Integration | ? | ? | |||||
Centrifuge Integration | ? | ? | ? | ? | |||
Drybath Integration | ? | ||||||
Esco Sublimate freeze dryer | ? | ? | ? | ? | |||
Refrigerated Microcentrifuge Integration | ? | ||||||
3rd party Freeze dryer | ? | ? | ? | ? |
Guide to Models
CBI-U-___-___-___-__
Isolator Unit | Model | Internal Width | No. of Gloves Ports | Voltage Code | Pressure | Airflow | NUMBER of PTC | Type of PTC | Sharps Bin inside | |||||||
Containment Barrier Isolator | CBI | Unidirectional | U | 1200mm | 2G | 220-240 VAC, 50/60 Hz | 8 | Negative | N | Recirculating | R | 1 Left | L | PTC0 to PTC7 (see PTC legend) | with sharps container provision | S |
1600mm | 3G | 1 Right | R | |||||||||||||
2000mm | 4G | 110-120 VAC, 50/60 Hz | 9 | Positive | P | Single Pass/Total Exhaust | S | Both Left and Right | B | without sharps container provision | 0 | |||||
No PTC | 0 |
LIST OF OPTIONS for CBI Models | CBI-U | CBI - T | CBI-III | CBI-H | |||
4" Split Butterfly Valve (for powder discharge of powder below isolator chamber) | ? | ? | |||||
Adjustable Hydraulic Stand (based on operator ID input) | ? | ? | ? | ||||
Exhaust Box (with automated dampers with inflatable seals or manual with valve) | ? | ? | ? | ||||
Anti-blow back damper box | ? | ? | ? | ||||
Automated Pressure Hold Test | with Client Supplied Compressed Air | ? | ? | ? | ? | ||
with On-board Air Compressor | ? | ? | ? | ? | |||
Bag Welder with Table Bag-out Port |
? | ? | ? | ||||
Bio Dunk Tank Bag Out Port |
? | ? | |||||
Mobile Biodecontamination BioVap TM | ? | ? | ? | ||||
Carbon Filter | ? | ||||||
Convertible to Class 1 cabinet | ? | ||||||
Integration of small scale aseptic or potent tablet/capsule etc… | ? | ? | ? | ? | |||
Double-sided access | ? | ? | ? | ||||
Manual Drain Ball Valve (for client controlled CIP/WP) must order with inner pass-through inflatable sealed doors. | ? | ? | |||||
Electrical Outlet (IP66) | IP 66 | ? | ? | ? | ? | ||
ATEX Zone 1/21 (only for internal environment) | ? | ? | ? | ||||
ATEX rating up to zone 1/21 internally only (ATEX fan, “IS” signals for internal door sensor/push button) | ? | ? | |||||
Glove Leak Tester | ? | ? | ? | ? | |||
Formalin Vaporizer (auto neutralization and purge cycle) | ? | ? | ? | ||||
H2O2 Monitoring (sensor is not integrated with HMI) | ? | ? | ? | ||||
Liquid Water Entry / Exit Ports | ? | ? | |||||
N2 Purge for Process Chamber | ? | ||||||
Ø250 mm Product Waste Bag Out Ports / | ? | ||||||
Battery option to maintain EM interlock during power outage or E Stop | ? | ? | ? | ? | |||
Particle Counter | Portable Paricle Counter (Non-viable) | ? | ? | ? | |||
Microbial Air Samples (Viable Particle Counter) | ? | ? | ? | ||||
Product Waste Entry / Exit Ports | ? | ? | |||||
RTPØ 105, 190, 270 - Alpha | ? | ? | ? | ? | |||
RTPØ 105, 190, 270 - Beta Canister | ? | ? | |||||
RTPØ 105, 190, 270 - Beta Liner | ? | ? | |||||
RTPØ 350, 460 - Alpha, Beta Liner, Beta Canister | ? | ? | ? | ||||
Service Fixtures (Vacuum, Nitrogen, Compressed Air, Nozzle for BioVap) | ? | ? | ? | ? | |||
Spray Ball (CIP) with Manual Ball Valve | ? | ||||||
Spray Gun (WIP) with Manual Ball Valve | ? | ? | |||||
Sterile Continuous Liner | ? | ? | ? | ||||
Sterility Test Pump | ? | ||||||
Temperature and Relative Humidity Monitoring (only for process chamber) | ? | ? | ? | ? | |||
Rear view monitor | ? | ? | ? | ? | |||
UV Lamp | ? | ? | |||||
Weighing Scale Granite Slab | ? | ? | ? | ||||
Sharps (inside) | ? |
EQUIPMENT INTEGRATION/ CUSTOMIZATION EXAMPLES | CBI-U | CBI - T | CBI-III | CBI-III/1 | |||
Autoclave | ? | ? | |||||
Analytical Balance | ? | ? | ? | ? | |||
Biosafety Cabinet | ? | ||||||
CCTV Camera | ? | ? | ? | ||||
CCTV Camera Provision | ? | ? | ? | ||||
Fume Cabinet Integration | ? | ||||||
Vacuum Oven / Tray Dryer integration | ? | ||||||
Non C02 Incubator Integration | ? | ? | ? | ||||
CO2 Incubator Integration | ? | ? | |||||
Centrifuge Integration | ? | ? | ? | ? | |||
Drybath Integration | ? | ||||||
Esco Sublimate freeze dryer | ? | ? | ? | ? | |||
Refrigerated Microcentrifuge Integration | ? | ||||||
3rd party Freeze dryer | ? | ? | ? | ? |